  2. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage is that, for a given capacity of a distribution system, it saves conductor material over a single-ended ...

  3. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    The Carter system, also known as the Chicago system, was a method of wiring three-way switches in the era of early knob-and-tube wiring. This now-obsolete wiring method has been prohibited by the USA National Electrical Code since 1923, [ 2 ] even in new knob-and-tube installations which are still permitted under certain circumstances.

  4. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common residential and small commercial service in Canada and the U.S., single split-phase, 240 V, features a neutral and two hot legs, 240 V to each other, and 120 V each to the neutral. The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral.

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.

  6. Two-wire circuit - Wikipedia

    en.wikipedia.org/wiki/Two-wire_circuit

    Two-wire circuits in new installations are limited to intercom and military field telephone applications, though these too are being supplanted by modern digital communication modes. To communicate in both directions in the same wire pair, conversion between four-wire and two-wire was necessary, both at the telephone and at the central office .

  7. Polyphase system - Wikipedia

    en.wikipedia.org/wiki/Polyphase_system

    In the very early days of commercial electric power, some installations used two-phase four-wire systems for motors. The chief advantage of these was that the winding configuration was the same as for a single-phase capacitor-start motor and, by using a four-wire system, conceptually the phases were independent and easy to analyse with mathematical tools available at the time.

  8. Two-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Two-phase_electric_power

    Two-phase electrical power was an early 20th-century polyphase alternating current electric power distribution system. Two circuits were used, with voltage phases differing by one-quarter of a cycle, 90°. Usually circuits used four wires, two for each phase. Less frequently, three wires were used, with a common wire with a larger-diameter ...

  9. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. The earth (or sometimes a body of water) is used as the return path for the current, to avoid the need for a second wire (or neutral wire ) to act as a ...