When.com Web Search

  1. Ads

    related to: hitachi uv vis spectrophotometer principle 1

Search results

  1. Results From The WOW.Com Content Network
  2. Ultraviolet–visible spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet–visible...

    A UV-Vis spectrophotometer is an analytical instrument that measures the amount of ultraviolet (UV) and visible light that is absorbed by a sample. It is a widely used technique in chemistry, biochemistry, and other fields, to identify and quantify compounds in a variety of samples.

  3. UV detectors - Wikipedia

    en.wikipedia.org/wiki/UV_detectors

    Figure 1: Simplified schemes of the Variable UV-Vis detector compared to PhotoDiode Array detector. In the Variable UV-Vis the entire optical bench is located before the flow cell whereas in the diode array the flow rate is positioned before the main optical bench. A schematic of the optical systems is shown in Figure 1.

  4. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Ultraviolet-visible (UV-vis) spectroscopy involves energy levels that excite electronic transitions. Absorption of UV-vis light excites molecules that are in ground-states to their excited-states. [5] Visible region 400–700 nm spectrophotometry is used extensively in colorimetry science. It is a known fact that it operates best at the range ...

  5. Ultraviolet–visible spectroscopy of stereoisomers - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet–visible...

    UVvis spectroscopy sees only chromophores, so other molecules must be prepared for analysis by chemical addition of a chromophore such as anthracene. Two methods are reported: the octant rule and the exciton chirality method. [1] The octant rule was introduced in 1961 by William Moffitt, R. B. Woodward, A. Moscowitz, William Klyne and Carl ...

  6. Variable pathlength cell - Wikipedia

    en.wikipedia.org/wiki/Variable_pathlength_cell

    In ultraviolet-visible spectroscopy or spectroscopy in general a 1 cm pathlength cuvette is used to measure samples. The cuvette is filled with sample, light is passed through the sample and intensity readings are taken. The slope spectroscopy technique can be applied using the same methods as in absorption spectroscopy.

  7. UV-Vis absorption spectroelectrochemistry - Wikipedia

    en.wikipedia.org/wiki/UV-Vis_absorption_spectro...

    It is the link between the electrochemistry and the UV-Vis absorption spectroscopy. [3] Devices to conduct the radiation beam: lenses, mirrors and/or optical fibers. The last ones conduct electromagnetic radiation over great distances with hardly any losses.

  8. DU spectrophotometer - Wikipedia

    en.wikipedia.org/wiki/DU_spectrophotometer

    [2]: 151 [34] [35] All modern UVVis spectrophotometer are built on the same basic principles as the DU spectrophotometer. [29] Diagram of Model DU optical system, Beckman manual, 1954 "Light from the tungsten lamp is focused by the condensing mirror and directed in a beam to the diagonal slit entrance mirror.

  9. Deuterium arc lamp - Wikipedia

    en.wikipedia.org/wiki/Deuterium_arc_lamp

    This is similar to the situation in a hydrogen flame. Arc lamps made with ordinary light-hydrogen provide a very similar UV spectrum to deuterium, and have been used in UV spectroscopes. However, lamps using deuterium have a longer life span and an emissivity (intensity) at the far end of their UV range which is three to five times that of an ...