When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. High-performance liquid chromatography - Wikipedia

    en.wikipedia.org/wiki/High-performance_liquid...

    HPLC most commonly uses a UV-Vis absorbance detector; however, a wide range of other chromatography detectors can be used. A universal detector that complements UV-Vis absorbance detection is the charged aerosol detector (CAD). A kind of commonly utilized detector includes refractive index detectors, which provide readings by measuring the ...

  3. Abbrev. [1]Meaning [1] Latin (or Neo-Latin) origin [1]; a.c. before meals: a.d., ad, AD right ear auris dextra a.m., am, AM morning: ante meridiem: nocte every night ...

  4. Specific ultraviolet absorbance - Wikipedia

    en.wikipedia.org/wiki/Specific_ultraviolet...

    To derive SUVA, first, UVC light (UV spectrum subtypes) at 254 nm or 280 nm, [2] is measured in units of absorbance per meter of path length, often the sample must be diluted with ultrapure water because absorbance can be high. [3]

  5. Ultraviolet–visible spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Ultraviolet–visible...

    A UV-Vis spectrophotometer is an analytical instrument that measures the amount of ultraviolet (UV) and visible light that is absorbed by a sample. It is a widely used technique in chemistry, biochemistry, and other fields, to identify and quantify compounds in a variety of samples.

  6. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    Then the photon flux density (watts per meter squared usually) of the transmitted or reflected light is measured with a photodiode, CCD or other light sensor. The transmittance or reflectance value for each wavelength of the test sample is then compared with the transmission or reflectance values from the reference sample.

  7. Photoinitiator - Wikipedia

    en.wikipedia.org/wiki/Photoinitiator

    In chemistry, a photoinitiator is a molecule that creates reactive species (free radicals, cations or anions) when exposed to radiation (UV or visible). Synthetic photoinitiators are key components in photopolymers (for example, photo-curable coatings, adhesives and dental restoratives).

  8. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  9. Spectronic 20 - Wikipedia

    en.wikipedia.org/wiki/Spectronic_20

    In this calibration, the transmittance is set at 100% using the calibration knob of the instrument (the amplifier control knob in the figure at right). The instrument can also optionally be calibrated with a stock solution of a sample at a concentration known to have an absorbance of 2 or else vendor supplied standards, using the light ...