When.com Web Search

  1. Ads

    related to: what does gas chromatography detect

Search results

  1. Results From The WOW.Com Content Network
  2. Thermal conductivity detector - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_detector

    The thermal conductivity detector (TCD), also known as a katharometer, is a bulk property detector and a chemical specific detector commonly used in gas chromatography. [1] This detector senses changes in the thermal conductivity of the column eluent and compares it to a reference flow of carrier gas. Since most compounds have a thermal ...

  3. Gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography

    Gas chromatography (GC) is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture. [ 1 ]

  4. Gas chromatography ion detector - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography_ion...

    Many gas chromatograph detectors are ion detectors with varying methods of ionizing the components eluting from the gas chromatograph's column. [1] [2] An ion detector is analogous to a capacitor or vacuum tube. It can be envisioned as two metal grids separated by air with inverse charges placed on them.

  5. Electron capture detector - Wikipedia

    en.wikipedia.org/wiki/Electron_capture_detector

    Electron capture detector developed by James Lovelock in the Science Museum, London Electron capture detector, Science History Institute. The electron capture detector is used for detecting electron-absorbing components (high electronegativity) such as halogenated compounds in the output stream of a gas chromatograph.

  6. Flame ionization detector - Wikipedia

    en.wikipedia.org/wiki/Flame_ionization_detector

    Most commonly, the FID is attached to a gas chromatography system. The eluent exits the gas chromatography column (A) and enters the FID detector’s oven (B). The oven is needed to make sure that as soon as the eluent exits the column, it does not come out of the gaseous phase and deposit on the interface between the column and FID.

  7. Gas chromatography–mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography–mass...

    The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...