When.com Web Search

  1. Ads

    related to: vivareal bh mg 50 ft 10 2 mc cable

Search results

  1. Results From The WOW.Com Content Network
  2. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    If the MI cable jacket has been damaged, the magnesium oxide will wick moisture into the cable, and it will lose its insulating properties, causing shorts to the copper cladding and thence to earth. It is often necessary to remove 0.5 to 2 metres (1.6 to 6.6 ft) of the MI cable and splice in a new section to accomplish the repair.

  3. List of international submarine communications cables

    en.wikipedia.org/wiki/List_of_international...

    WACS – (West Africa Cable System) (South Africa, Namibia, Angola, the Democratic Republic of the Congo, the Republic of Congo, Cameroon, Nigeria, Togo, Ghana, Côte d'Ivoire, Cape Verde, Canary Islands, Portugal, United Kingdom)

  4. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    The equation in section 310-15(C) of the National Electrical Code, called the Neher–McGrath equation (NM), may be used to estimate the effective ampacity of a cable: [3] = (+) (+), In the equation, T c {\textstyle T_{c}} is normally the limiting conductor temperature derived from the insulation or tensile strength limitations.

  5. High-voltage direct current - Wikipedia

    en.wikipedia.org/wiki/High-voltage_direct_current

    Long distance HVDC lines carrying hydroelectricity from Canada's Nelson River to this converter station where it is converted to AC for use in southern Manitoba's grid. A high-voltage direct current (HVDC) electric power transmission system uses direct current (DC) for electric power transmission, in contrast with the more common alternating current (AC) transmission systems. [1]

  6. Ethernet over coax - Wikipedia

    en.wikipedia.org/wiki/Ethernet_over_coax

    The first Ethernet standard, known as 10BASE5 (ThickNet) in the family of IEEE 802.3, specified baseband operation over 50 ohm coaxial cable, which remained the principal medium into the 1980s, when 10BASE2 (ThinNet) coax replaced it in deployments in the 1980s; both being replaced in the 1990s when thinner, cheaper twisted pair cabling came to dominate the market.

  7. VLF cable testing - Wikipedia

    en.wikipedia.org/wiki/VLF_cable_testing

    VLF cable testing (Very Low Frequency) is a technique for testing of medium and high voltage (MV and HV) cables. VLF systems are advantageous in that they can be manufactured to be small and lightweight; making them useful – especially for field testing where transport and space can be issues.

  8. Maximum energy product - Wikipedia

    en.wikipedia.org/wiki/Maximum_energy_product

    BH) max can be graphically defined as the area of the largest rectangle that can drawn in the second quadrant of the B-H loop. The maximum energy product is defined based on the magnetic hysteresis saturation loop ( B - H curve), in the demagnetizing portion where the B and H fields are in opposition.

  9. Aerial bundled cable - Wikipedia

    en.wikipedia.org/wiki/Aerial_bundled_cable

    In the Dandenong Ranges area Victoria 2014. Medium voltage (11-22 kV) ABC is being replaced with underground cable due to high failure rates of HV ABC, with life expectancy of just 10 years, when original life was expected to be approx 30 years. Due to degraded cable, cost of repairs & maintenance and bushfire risk.