  2. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  4. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Cold water cisterns, where the float valve outlet must be above the overflow water level. The previous practice of taking a "silencing tube" from the float valve to under the water level is no longer acceptable. Under some plumbing codes. Such silencing may still be acceptable if it is a soft collapsible tube which cannot syphon.

  5. Water hammer - Wikipedia

    en.wikipedia.org/wiki/Water_hammer

    To keep water hammer low, pipe-sizing charts for some applications recommend flow velocity at or below 1.5 m/s (4.9 ft/s). Fit slowly closing valves. Toilet fill valves are available in a quiet fill type that closes quietly. Non-slam check valves do not rely on fluid flow to close and will do so before the water flow reaches significant velocity.

  6. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  7. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  8. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.

  9. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...