  1. Results From The WOW.Com Content Network
  2. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    From 1987 onwards, a step-wise shift towards 230 +13.8 −23 V was implemented. From 2009 on, the voltage is permitted to be 230 ± 23 V. [8] [9] No change in voltage was required by either the Central European or the UK system, as both 220 V and 240 V fall within the lower 230 V tolerance bands (230 V ±6%). Usually the voltage of 230 V ±3% ...

  3. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...

  4. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    If heating equipment designed for a 240-volt system is connected to two phases of a 208-volt supply, it will produce only 75% of its rated heating effect. Single-phase motors may have taps to allow their use on either 208-volt or 240-volt supply.

  5. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    120/208 V 277/480 V 120/240 V 240/208/120 V 240 V 480 V 60 Hz [22] NEMA 5-20R outlets, which are similar to type B but have a T-shaped neutral slot, are sometimes used for higher current 120 V commercial equipments (up to 20 A). On the other hand, NEMA 10-50P outlets are sometimes used for 208 V and 240 V industrial equipments (up to 50 A).

  6. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    In Europe, three-phase 230/400 V is most commonly used. However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current.

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 6 devices, while specified as 250 V, may be used for either 208 or 240 V circuits, generally depending on whether the building has a three-phase or split-phase power supply, respectively. The NEMA 6-20R or 6-30R found in many hotel and motel rooms is typically supplied with either split-phase or two phases of three-phase 208 V.

  8. Vegan vs. vegetarian vs. omnivore: Does diet type have a big ...

    www.aol.com/vegan-vs-vegetarian-vs-omnivore...

    When comparing vegan, vegetarian, and omnivore diet types, researchers found that food quality and diversity may have the biggest impact on the health and structure of the gut microbiome.

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...