Search results

  1. Results From The WOW.Com Content Network
  2. Lightning arrester - Wikipedia

    en.wikipedia.org/wiki/Lightning_arrester

    Lightning arresters used in power substations are large devices, consisting of a porcelain tube several feet long and several inches in diameter, typically filled with discs of zinc oxide. A safety port on the side of the device vents the occasional internal explosion without shattering the porcelain cylinder.

  3. Lightning rod - Wikipedia

    en.wikipedia.org/wiki/Lightning_rod

    A lightning arrester is a device, essentially an air gap between an electric wire and ground, used on electric power systems and telecommunication systems to protect the insulation and conductors of the system from the damaging effects of lightning. The typical lightning arrester has a high-voltage terminal and a ground terminal.

  4. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A substation is a part of an electrical generation, transmission, ... Line entrance surge arrestors are used to protect substation equipment accordingly.

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Power engineering. In electric power distribution, automatic circuit reclosers (ACRs) are a class of switchgear designed for use on overhead electricity distribution networks to detect and interrupt transient faults. Also known as reclosers or autoreclosers, ACRs are essentially rated circuit breakers with integrated current and voltage sensors ...

  6. Electrical substation - Wikipedia

    en.wikipedia.org/wiki/Transformer_substation

    A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels.

  7. IEC 61000-4-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-5

    IEC 61000-4-5 defines test set-up, procedures, and classification levels. In particular, it standardizes the required surge voltage and current waveforms for laboratory testing, with the "1.2/50-8/20 μs" impulse being the most frequently used surge waveform. Although this standard is designed for testing equipment as a whole at system level ...

  8. HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter_station

    An HVDC converter station (or simply converter station) is a specialised type of substation which forms the terminal equipment for a high-voltage direct current (HVDC) transmission line. [1] It converts direct current to alternating current or the reverse. In addition to the converter, the station usually contains: three-phase alternating ...

  9. Electrical grid - Wikipedia

    en.wikipedia.org/wiki/Electrical_grid

    The substation busbar: typically a set of three conductors, one for each phase of current. The substation is organized around the buses, and they are connected to incoming lines, transformers, protection equipment, switches, and the outgoing lines. [27] Lightning arresters; Capacitors for power factor correction