When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Fire sprinkler system. A glass bulb type sprinkler head will spray water into the room if sufficient heat reaches the bulb and causes it to shatter. Sprinkler heads operate individually. Note the red liquid in the glass bulb. A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate ...

  3. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    A fire alarm notification appliance as widely used under North American standards. A fire alarm system is a building system designed to detect, alert occupants, and alert emergency forces of the presence of fire, smoke, carbon monoxide, or other fire-related emergencies. Fire alarm systems are required in most commercial buildings.

  4. NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/NFPA_704

    NFPA 704 safety squares on containers of ethyl alcohol and acetone. " NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response " is a standard maintained by the U.S. -based National Fire Protection Association. First "tentatively adopted as a guide" in 1960, [1] and revised several times since then, it ...

  5. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...

  6. NFPA 72 - Wikipedia

    en.wikipedia.org/wiki/NFPA_72

    The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components." [1]

  7. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year. In buildings protected by properly ...

  8. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    A fire door is a door with a fire-resistance rating (sometimes referred to as a fire protection rating for closures) used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship.

  9. Manual fire alarm activation - Wikipedia

    en.wikipedia.org/wiki/Manual_fire_alarm_activation

    Manual fire alarm activation. An activated manual call point in Japan. Telephone jacks are visible beneath the open cover. Manual fire alarm activation is the process of triggering a fire alarm through a call point, pull station, or other device. This usually causes the alarm to sound the evacuation signal for the relevant building or zone.