Search results
Results From The WOW.Com Content Network
Diffusing capacity of the lung (D L) (also known as transfer factor) measures the transfer of gas from air in the lung, to the red blood cells in lung blood vessels. It is part of a comprehensive series of pulmonary function tests to determine the overall ability of the lung to transport gas into and out of the blood.
Pulmonary function: increased residual volume, increased total lung capacity, fixed obstruction, low diffusing capacity of the lung for carbon monoxide that corrects with alveolar volume; High-resolution CT scan: diffuse pulmonary nodules 4–10 mm, greater than 20 nodules, mosaic attenuation or air trapping in greater than 50% of the lung
Pulmonary function testing (PFT) is a complete evaluation of the respiratory system including patient history, physical examinations, and tests of pulmonary function. The primary purpose of pulmonary function testing is to identify the severity of pulmonary impairment. [ 1 ]
The diffusing capacity for carbon monoxide (DLCO) is invariably reduced in IPF and may be the only abnormality in mild or early disease. Its impairment underlies the propensity of patients with IPF to exhibit oxygen desaturation with exercise which can also be evaluated using the 6-minute walk test (6MWT).
In obstructive lung disease, the FEV1 is reduced due to an obstruction of air escaping from the lungs. Thus, the FEV1/FVC ratio will be reduced. [4] More specifically, according to the National Institute for Clinical Excellence, the diagnosis of COPD is made when the FEV 1 /FVC ratio is less than 0.7 or [8] the FEV 1 is less than 75% of predicted; [9] however, other authoritative bodies have ...
In obstructive lung disease however, the FEV1/FVC is less than 0.7, indicating that FEV1 is significantly reduced when compared to the total expired volume. This indicates that the FVC is also reduced, but not by the same ratio as FEV1. [8] One definition requires a total lung capacity which is 80% or less of the expected value. [9]
Diffusing capacity (or DLCO) is the carbon monoxide uptake from a single inspiration in a standard time (usually 10 seconds). During the test the person inhales a test gas mixture that consisting of regular air that includes an inert tracer gas and CO, less than one percent.
Closing capacity (CC), which equals CV + (TLC - VC), with VC taken from the curve acquired from the nitrogen washout test. [3] As a reference, it should be 70% to 130% of what is the average value in the population, [4] which, in turn, may vary with geographic location. Mean slope of the alveolar plateau (phase III).