Search results

  1. Results From The WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power factor correction brings the power factor of an AC power circuit closer to 1 by supplying or absorbing reactive power, adding capacitors or inductors that act to cancel the inductive or capacitive effects of the load, respectively. In the case of offsetting the inductive effect of motor loads, capacitors can be locally connected.

  3. Valley-fill circuit - Wikipedia

    en.wikipedia.org/wiki/Valley-fill_circuit

    A valley-fill circuit is a type of passive power-factor correction ... US6141230A, provides a power factor of 0.98 and a THD of 9.61% and is most suited to constant ...

  4. Active rectification - Wikipedia

    en.wikipedia.org/wiki/Active_rectification

    Using active rectification to implement AC/DC conversion allows a design to undergo further improvements (with more complexity) to achieve an active power factor correction, which forces the current waveform of the AC source to follow the voltage waveform, eliminating reactive currents and allowing the total system to achieve greater efficiency.

  5. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    However, the maximum power theorem does not apply to its "downstream" connection. That connection is an impedance bridging connection; it emulates a high-voltage, low-resistance source to maximize efficiency. On the power grid the overall load is usually inductive. Consequently, power factor correction is most commonly achieved with banks of ...

  6. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    For instance, a power factor of 0.68 means that only 68 percent of the total current supplied (in magnitude) is actually doing work; the remaining current does no work at the load. Power Factor is very important in Power sector substations. Form the national grid the sub sectors are required to have minimum amount of power factor.

  7. Synchronous condenser - Wikipedia

    en.wikipedia.org/wiki/Synchronous_condenser

    Its principal advantage is the ease with which the amount of correction can be adjusted. Synchronous condensers are an alternative to capacitor banks and static VAR compensators for power-factor correction in power grids. [3] One advantage is that the amount of reactive power from a synchronous condenser can be continuously adjusted.

  8. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    This is traditionally done using shunt capacitors and inductors (reactors), [13] much like Power Factor Correction. The most common shunt compensation device is the Static VAR Compensator (SVC). [14] SVCs use power electronics, generally Thyristors, to switch fixed capacitors and reactors.

  9. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    In Electrical Engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks. [1] [2] SVCs are part of the flexible AC transmission system [3] [4] device family, regulating voltage, power factor, harmonics and stabilizing the system. A static ...