When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Kjeldahl method - Wikipedia

    en.wikipedia.org/wiki/Kjeldahl_method

    If boric acid (or some other weak acid) was used, direct acid–base titration is done with a strong acid of known concentration. HCl or H 2 SO 4 can be used. Indirect back titration is used instead if strong acids were used to make the standard acid solution: strong base of known concentration (like NaOH) is used to neutralize the solution. In ...

  3. Potentiometric titration - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_titration

    Measurements, first and second derivative in a potentiometric titration. In analytical chemistry, potentiometric titration is a technique similar to direct titration of a redox reaction. It is a useful means of characterizing an acid. No indicator is used; instead the electric potential is measured across the analyte, typically an electrolyte ...

  4. Primary standard - Wikipedia

    en.wikipedia.org/wiki/Primary_standard

    Some examples of primary standards for titration of solutions, based on their high purity, are provided: [4] Arsenic trioxide for making sodium arsenite solution for standardisation of sodium periodate solution (until Ph. Eur. 3, Appendix 2001 also for iodine and cerium(IV) sulfate solutions, since Ph. Eur. 4, 2002 standardised by sodium ...

  5. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    The volumetric titration is based on the same principles as the coulometric titration, except that the anode solution above now is used as the titrant solution. The titrant consists of an alcohol (ROH), base (B), SO 2 and a known concentration of I 2. Pyridine has been used as the base in this case. One mole of I 2 is consumed for each mole of ...

  6. Iodometry - Wikipedia

    en.wikipedia.org/wiki/Iodometry

    Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary iodine indicates the end point. Note that iodometry involves indirect titration of iodine liberated by reaction with the analyte, whereas iodimetry involves direct titration using iodine as ...

  7. Isotope dilution - Wikipedia

    en.wikipedia.org/wiki/Isotope_dilution

    Calibration curves are obtained by plotting measured isotope ratios in the prepared blends against the known ratio of the sample mass to the mass of the spike solution in each blend. Isotope dilution calibration plots sometimes show nonlinear relationships and in practice polynomial fitting is often performed to empirically describe such curves.

  8. Titer - Wikipedia

    en.wikipedia.org/wiki/Titer

    The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.

  9. Gran plot - Wikipedia

    en.wikipedia.org/wiki/Gran_plot

    The pH meter is usually calibrated with buffer solutions at known pH values before starting the titration. The ionic strength can be kept constant by judicious choice of acid and base. For instance, HCl titrated with NaOH of approximately the same concentration will replace H + with an ion (Na + ) of the same charge at the same concentration ...