Ad
related to: refrigerant recovery process and guide sheet pdf sample form
Search results
Results From The WOW.Com Content Network
The EPA defines refrigerant reclamation as "Reclaim refrigerant means to reprocess refrigerant to at least the purity specified in appendix A to 40 CFR part 82, subpart F (based on AHRI Standard 700–1993, Specifications for Fluorocarbon and Other Refrigerants) and to verify this purity using the analytical methodology prescribed in appendix A ...
Trichlorofluoromethane was first widely used as a refrigerant.Because of its high boiling point compared to most refrigerants, it can be used in systems with a low operating pressure, making the mechanical design of such systems less demanding than that of higher-pressure refrigerants R-12 or R-22.
According to ASHRAE standard 34, the R-number of a chemical refrigerant is assigned systematically according to its molecular structure and has between two and four digits. If there are carbon -carbon multiple bonds , there are four digits in all: the number of these bonds is the first digit and the number of carbon atoms minus one (C-1) is next.
For Type I systems the main requirement is to remove 80% of the refrigerant if the appliance's compressor is not running and 90% if running and evacuate to a 4 inch Hg vacuum. For Type II or Type III applications, the appliance must be evacuated to the following levels for device manufactured after November 15, 1993 in order to recover the ...
Dichlorodifluoromethane (R-12 or CFC-12), the most commonly used Freon brand refrigerant prior to its ban in many countries in 1996 and total ban in 2010. 1,1,1,2-Tetrafluoroethane (R-134a or HFC-134a), one of the main replacements for the formerly widespread R-12. Opteon halogenated olefins now replacing Freons in many applications.
HCFC-123 is used in large tonnage centrifugal chiller applications, and is the most efficient refrigerant currently in use in the marketplace for HVAC applications. HCFC-123 is also used as a testing agent for bypass leakage of carbon adsorbers in gas filtration systems, and as the primary chemical in Halotron I fire-extinguishing agent. [2]
This is an auto-cascade process with two different refrigerants. The high-temperature refrigerant (red) condenses in the air condenser and is then separated and evaporated to cool the heat exchanger, which condenses the low-temperature refrigerant (blue). Purple signifies a mixture of both refrigerants.
1,1-Difluoroethane, or DFE, is an organofluorine compound with the chemical formula C 2 H 4 F 2.This colorless gas is used as a refrigerant, where it is often listed as R-152a (refrigerant-152a) or HFC-152a (hydrofluorocarbon-152a).