The resistance of copper wire is approximately 1 Ω / 1000 ft for 10 AWG, 10 Ω / 1000 ft for 20 AWG, 100 Ω / 1000 ft for 30 AWG, and so on. [ 5 ] : 27 For an arbitrary gauge n , it's approximately 10 n /10 Ω per 10 000 ft .
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...
Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...
The first rubber-insulated cables for US building wiring were introduced in 1922 with US patent 1458803, Burley, Harry & Rooney, Henry, "Insulated electric wire", issued 1923-06-12, assigned to Boston Insulated Wire and Cable . These were two or more solid copper electrical wires with rubber insulation, plus woven cotton cloth over each ...
A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.
Like the European modular furniture, display cabinets, ceiling tile grids, etc. they were designed for, these are based on multiples of the 300 mm (11.8 in) "metric foot" instead of the 12 in (305 mm) imperial foot, but are all 37 mm (1.5 in) shorter to allow space for the lampholder connections within the 300 mm modular units, and for much ...
Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...
IEC 60364 Electrical Installations for Buildings is the International Electrotechnical Commission (IEC)'s international standard on electrical installations of buildings.This standard is an attempt to harmonize national wiring standards in an IEC standard and is published in the European Union by CENELEC as "HD 60364".