Search results
Results From The WOW.Com Content Network
The Basic Officer Leader Course (BOLC) is a two-phased training course designed to commission officers and prepare them for service in the United States Army.Prospective officers complete Phase I (BOLC A) as either a cadet (United States Military Academy or Reserve Officers' Training Corps) or an officer candidate (Officer Candidate School (United States Army)) before continuing on to BOLC B ...
This is done by multiplying 1.5 MAWP by the ratio of the allowable stress at the test temperature to allowable stress at the design temperature per ASME B31.3 Section 345.4.2 Equation 24. Test pressures need not exceed a value that would produce a stress higher than yield stress at test temperature. ASME B31.3 section 345.4.2 (c)
To ensure consistency and repeatability, the methods use in the chemical analysis of water samples are often agreed and published at a national or state level. By convention these are often referred to as "Blue book". [4] [5] Certain analyses are performed in-field (e.g. pH, specific conductance) while others involve sampling and laboratory ...
Most commonly an aquifer test is conducted by pumping water from one well at a steady rate and for at least one day, while carefully measuring the water levels in the monitoring wells. When water is pumped from the pumping well the pressure in the aquifer that feeds that well declines.
A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation, the water pressure can be boosted by means of a fire pump.
Thermodynamic pump testing is a form of pump testing where only the temperature rise, power consumed, and differential pressure need to be measured to find the efficiency of a pump. These measurements are typically made with insertion temperature probes and pressure probes fitted to tapping points on the pump's inlet and outlet. [ 1 ]
Example Number 1: A tank with a liquid level 2 metres above the pump intake, plus the atmospheric pressure of 10 metres, minus a 2 metre friction loss into the pump (say for pipe & valve loss), minus the NPSH R curve (say 2.5 metres) of the pre-designed pump (see the manufacturers curve) = an NPSH A (available) of 7.5 metres. (not forgetting ...
The basic function of a pump is to do work on a liquid. It can be used to transport and compress a liquid. In industries heavy-duty pumps are used to move water, chemicals, slurry, food, oil and so on. Depending on their action, pumps are classified into two types — Centrifugal Pumps and Positive Displacement Pumps. While centrifugal pumps ...