When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example delta-wye transformer schematic. A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three ...

  3. Y-Δ transform - Wikipedia

    en.wikipedia.org/wiki/Y-Δ_transform

    For that, equivalent wye connections are used for generators, transformers, loads and motors. The stator windings of a practical delta-connected three-phase generator, shown in the following figure, can be converted to an equivalent wye-connected generator, using the six following formulas [a]: Practical generator connected in delta/triangle/pi.

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  7. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Examples of connections are wye-delta, delta-wye, delta-delta, and wye-wye. A vector group indicates the configuration of the windings and the phase angle difference between them. If a winding is connected to earth , the earth connection point is usually the center point of a wye winding.

  8. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.

  9. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.