When.com Web Search

  1. Ads

    related to: electric motor amps calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    If two motors with the same and torque work in tandem, with rigidly connected shafts, the of the system is still the same assuming a parallel electrical connection. The K M {\displaystyle K_{\text{M}}} of the combined system increased by 2 {\displaystyle {\sqrt {2}}} , because both the torque and the losses double.

  3. Inrush current - Wikipedia

    en.wikipedia.org/wiki/Inrush_current

    Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on. Alternating-current electric motors and transformers may draw several times their normal full-load current when first energized, for a few cycles of the input waveform.

  4. Electric motor - Wikipedia

    en.wikipedia.org/wiki/Electric_motor

    An industrial electric motor . An electric motor is a machine that converts electrical energy into mechanical energy.Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force in the form of torque applied on the motor's shaft.

  5. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period. A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y').

  6. Orders of magnitude (current) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(current)

    One typical 12 V motor vehicle headlight (typically 60 W) 9 A 230 V AC, toaster, kettle (2 kW) 10 1: 10 or 20 A 230 V AC, Europe common domestic circuit breaker rating 15 or 20 A 120 V AC, United States, Canada and Mexico domestic circuit breaker rating 16.6 A 120 V AC, toaster, kettle (2 kW) 20 A 230 V AC, Immersion heater (4.6 kW) 24 A

  7. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase induction motor has a simple design, inherently high starting torque and high efficiency. Such motors are applied in industry for many applications. A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three ...

  8. Traction motor - Wikipedia

    en.wikipedia.org/wiki/Traction_motor

    This assumes that the electrical generator converts 90% of the engine's output into electrical energy and the traction motors convert 90% of this electrical energy back into mechanical energy. [citation needed] Calculation: 0.9 × 0.9 = 0.81 Individual traction motor ratings usually range up 1,600 kW (2,100 hp).

  9. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t