When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Continuous cooling transformation - Wikipedia

    en.wikipedia.org/wiki/Continuous_cooling...

    A continuous cooling transformation (CCT) phase diagram is often used when heat treating steel. [1] These diagrams are used to represent which types of phase changes will occur in a material as it is cooled at different rates. These diagrams are often more useful than time-temperature-transformation diagrams because it is more convenient to ...

  3. Magnetic refrigeration - Wikipedia

    en.wikipedia.org/wiki/Magnetic_refrigeration

    In practice, the magnetic field is decreased slowly in order to provide continuous cooling and keep the sample at an approximately constant low temperature. Once the field falls to zero or to some low limiting value determined by the properties of the refrigerant, the cooling power of the ADR vanishes, and heat leaks will cause the refrigerant ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The CLF is the cooling load at a given time compared to the heat gain from earlier in the day. [1] [5] The SC, or shading coefficient, is used widely in the evaluation of heat gain through glass and windows. [1] [5] Finally, the SCL, or solar cooling load factor, accounts for the variables associated with solar heat load.

  5. Isothermal transformation diagram - Wikipedia

    en.wikipedia.org/wiki/Isothermal_transformation...

    TTT diagram of isothermal transformations of a hypoeutectoid carbon steel; showing the main components obtained when cooling the steel and its relation with the Fe-C phase diagram of carbon steels. Austenite is slightly undercooled when quenched below Eutectoid temperature. When given more time, stable microconstituents can form: ferrite and ...

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    It can be via operable windows, louvers, or trickle vents when spaces are small and the architecture permits. ASHRAE defined Natural ventilation as the flow of air through open windows, doors, grilles, and other planned building envelope penetrations, and as being driven by natural and/or artificially produced pressure differentials. [1]

  7. Austempering - Wikipedia

    en.wikipedia.org/wiki/Austempering

    The specific cooling rate that is necessary to avoid the formation of pearlite is a product of the chemistry of the austenite phase and thus the alloy being processed. The actual cooling rate is a product of both the quench severity, which is influenced by quench media, agitation, load (quenchant ratio, etc.), and the thickness and geometry of ...

  8. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    A two-cycle cascade refrigeration process schematic diagram. A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1]

  9. Computer cooling - Wikipedia

    en.wikipedia.org/wiki/Computer_cooling

    An all-in-one (AIO) cooling unit, installed in a case DIY water cooling setup showing a 12 V pump, CPU waterblock and the typical application of a T-Line Schematic of a regular liquid cooling setup for PCs. Liquid cooling is a highly effective method of removing excess heat, with the most common heat transfer fluid in desktop PCs being ...

  1. Related searches continuous cooling diagrams for windows pdf printable calendar for september 23 2021

    continuous cooling diagramscontinuous cooling schematic
    continuous cooling phase diagramcontinuous cooling transformation