Search results
Results From The WOW.Com Content Network
Carotid ultrasound is a low-cost, noninvasive, and accurate diagnostic imaging modality used to evaluate diseases of the carotid arteries. [2] It is most often used to diagnose carotid artery stenosis, a form of atherosclerosis , and has the capability to assess plaque morphology and characteristics. [ 1 ]
Based on the NASCET (The North American Symptomatic Carotid Endarterectomy Trial) criteria, the degree of carotid stenosis is defined as: [22] percent stenosis = ( 1 − ( minimum diameter within stenosis) / ( poststenotic diameter ) ) × 100%. Calculators have been developed to facilitate grading of carotid stenosis per NASCET criteria. [23]
Velocity Time Integral is a clinical Doppler ultrasound measurement of blood flow, equivalent to the area under the velocity time curve. The product of VTI (cm/stroke) and the cross sectional area of a valve (cm2) yields a stroke volume (cm3/stroke), which can be used to calculate cardiac output.
The sign is an imaging finding using a 3.5–7.5 MHz ultrasound probe in the fourth and fifth intercostal spaces in the anterior clavicular line using the M-Mode of the machine. This finding is seen in the M-mode tracing as pleura and lung being indistinguishable as linear hyperechogenic lines and is fairly reliable for diagnosis of a pneumothorax.
Ultrasound measurements of carotid IMT were first proposed and validated in vitro by Paolo Pignoli in 1984 [2] and further details were subsequently published in a highly cited article. [3] The use of IMT as a non-invasive tool to track changes in arterial walls has increased substantially since the mid-1990s. [ 1 ]
Medical ultrasound includes diagnostic techniques (mainly imaging techniques) using ultrasound, as well as therapeutic applications of ultrasound. In diagnosis, it is used to create an image of internal body structures such as tendons, muscles, joints, blood vessels, and internal organs, to measure some characteristics (e.g., distances and velocities) or to generate an informative audible sound.
Pulse wave velocity (PWV) is the velocity at which the blood pressure pulse propagates through the circulatory system, usually an artery or a combined length of arteries. [1] PWV is used clinically as a measure of arterial stiffness and can be readily measured non-invasively in humans, with measurement of carotid to femoral PWV (cfPWV) being ...
In ultrasound it is usually measured from the velocity gradient SR = (v 2 - v 1)/L where v 2 and v 1 are the myocardial velocities at two different points, and L is the instantaneous distance between them. This is thus equivalent to the velocity difference per length unit (the spatial derivative of velocity) and has the unit s −1. Strain is ...