In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
SCMVA is defined as a product of the voltage before the 3LG fault and the current that would flow after the fault (this worst-case combination will not happen in practice, but provides a useful estimation of the capacity of the circuit). SCMVA is also called a short circuit level (SCL), [3] although sometimes the term SCL is used to designate ...
A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.
It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.
The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...
Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating ...
Short-circuit inductance is one of the parameters that determines the resonance frequency of the magnetic phase synchronous coupling in a resonant transformer and wireless power transfer. Short-circuit inductance is the main component of the current-limiting parameter in leakage transformer applications.
Short circuit ratio (or SCR) has multiple meanings: Short circuit ratio (synchronous generator) , a value used to characterize the stability of an electromechanical generator Short circuit ratio (electrical grid) , a metric to characterize the grid strength ("stiffness").