  1. Results From The WOW.Com Content Network
  2. Westgard rules - Wikipedia

    en.wikipedia.org/wiki/Westgard_Rules

    2 consecutive measurements exceed 2 standard deviations of the reference range, and on the same side of the mean. Inaccuracy and/or imprecision R 4s: Two measurements in the same run have a 4 standard deviation difference (such as one exceeding 2 standard deviations above the mean, and another exceeding 2 standard deviations below the mean).

  3. Laboratory quality control - Wikipedia

    en.wikipedia.org/wiki/Laboratory_quality_control

    An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well. The distance from the mean is measured in standard deviations.

  4. Standard deviation - Wikipedia

    en.wikipedia.org/wiki/Standard_deviation

    The mean and the standard deviation of a set of data are descriptive statistics usually reported together. In a certain sense, the standard deviation is a "natural" measure of statistical dispersion if the center of the data is measured about the mean. This is because the standard deviation from the mean is smaller than from any other point.

  5. Detection limit - Wikipedia

    en.wikipedia.org/wiki/Detection_limit

    The instrument detection limit (IDL) is the analyte concentration that is required to produce a signal greater than three times the standard deviation of the noise level. This may be practically measured by analyzing 8 or more standards at the estimated IDL then calculating the standard deviation from the measured concentrations of those standards.

  6. External quality assessment - Wikipedia

    en.wikipedia.org/wiki/External_quality_assessment

    For this reason, laboratory employees might treat EQA test items differently. [3] ... The most popular score is the Z-score, also called standard deviation index (SDI ...

  7. Measurement uncertainty - Wikipedia

    en.wikipedia.org/wiki/Measurement_uncertainty

    In metrology, measurement uncertainty is the expression of the statistical dispersion of the values attributed to a quantity measured on an interval or ratio scale.. All measurements are subject to uncertainty and a measurement result is complete only when it is accompanied by a statement of the associated uncertainty, such as the standard deviation.

  8. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  9. Reproducibility - Wikipedia

    en.wikipedia.org/wiki/Reproducibility

    Then, the standard deviation of the difference between two values obtained within the same laboratory is called repeatability. The standard deviation for the difference between two measurement from different laboratories is called reproducibility. [8] These measures are related to the more general concept of variance components in metrology.