Although EEG and MEG signals originate from the same neurophysiological processes, there are important differences. [38] Magnetic fields are less distorted than electric fields by the skull and scalp, which results in a better spatial resolution of the MEG.
A barrier in the widespread usage of MEG is due to pricing, as MEG systems can cost millions of dollars. EEG is a much more widely used method to achieve such temporal resolution as EEG systems cost much less than MEG systems. A disadvantage of EEG and MEG is that both methods have poor spatial resolution when compared to fMRI. [33]
EEG-fMRI (short for EEG-correlated fMRI or electroencephalography-correlated functional magnetic resonance imaging) is a multimodal neuroimaging technique whereby EEG and fMRI data are recorded synchronously for the study of electrical brain activity in correlation with haemodynamic changes in brain during the electrical activity, be it normal function or associated with disorders.
Since an EEG voltage signal represents a difference between the voltages at two electrodes, the display of the EEG for the reading encephalographer may be set up in one of several ways. The representation of the EEG channels is referred to as a montage. Sequential montage
For instance, MEG and EEG record the magnetic or electrical fluctuations that occur when a population of neurons is active. These methods are excellent for measuring the time-course of neural events (on the order of milliseconds,) but generally bad at measuring where those events happen.
The EEG proved to be a useful source in recording brain activity over the ensuing decades. However, it tended to be very difficult to assess the highly specific neural process that are the focus of cognitive neuroscience because using pure EEG data made it difficult to isolate individual neurocognitive processes. Event-related potentials (ERPs ...
Combining EEG with fMRI is hence potentially powerful because the two have complementary strengths—EEG has high temporal resolution, and fMRI high spatial resolution. But simultaneous acquisition needs to account for the EEG signal from varying blood flow triggered by the fMRI gradient field, and the EEG signal from the static field. [ 70 ]
EEG, ECG, EOG and EMG are measured with a differential amplifier which registers the difference between two electrodes attached to the skin. However, the galvanic skin response measures electrical resistance and the Magnetoencephalography (MEG) measures the magnetic field induced by electrical currents (electroencephalogram) of the brain.