When.com Web Search

  1. Ad

    related to: how to calculate room ventilation cost formula physics lab test

Search results

  1. Results From The WOW.Com Content Network
  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Negative room pressure - Wikipedia

    en.wikipedia.org/wiki/Negative_room_pressure

    Schematic of a network of rooms where air (shown in blue) flows in one direction from the corridor into the negative pressure room (green). Exhaust air is safely removed from the area through a ventilation system. Negative pressure is generated and maintained in a room by a ventilation system that continually attempts to move air out of the ...

  4. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    An airtight building has several positive impacts [3] when combined with an appropriate ventilation system (whether natural, mechanical, or hybrid): [4] Lower heating bills due to less heat loss, with potentially smaller requirements for heating and cooling equipment capacities; Better performing ventilation system

  5. Dilution (equation) - Wikipedia

    en.wikipedia.org/wiki/Dilution_(equation)

    V = air or gas volume of the closed space or room in cubic feet, cubic metres or litres; Q = ventilation rate into or out of the room in cubic feet per minute, cubic metres per hour or litres per second; C initial = initial concentration of a vapor inside the room measured in ppm; C final = final reduced concentration of the vapor inside the ...

  6. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    ASHRAE Standard 62.2 was adopted in 2004; it clarifies the ventilation air requirements for low-rise residences. The Standard specifies that forced ventilation is required in houses with infiltration less than 0.35 ACH. [2] This is typically accomplished with heat recovery ventilation or exhaust fans running constantly or periodically.

  7. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    Test results of the best systems are around 4.5. When measuring installed units over a whole season and accounting for the energy needed to pump water through the piping systems, seasonal COP's for heating are around 3.5 or less. This indicates room for further improvement.

  8. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect. The stack effect can be useful to drive natural ventilation in certain climates, but in other circumstances may be a cause of unwanted air infiltration or fire ...

  9. Computational fluid dynamics - Wikipedia

    en.wikipedia.org/wiki/Computational_fluid_dynamics

    In addition to the wide range of length and time scales and the associated computational cost, the governing equations of fluid dynamics contain a non-linear convection term and a non-linear and non-local pressure gradient term. These nonlinear equations must be solved numerically with the appropriate boundary and initial conditions.