When.com Web Search

  1. Ads

    related to: ipc 1 to 511 wire amp

Search results

  1. Results From The WOW.Com Content Network
  2. Wiring Harness Manufacturer's Association - Wikipedia

    en.wikipedia.org/wiki/Wiring_Harness_Manufacturer...

    The Wiring Harness Manufacturer's Association is a trade group for American manufacturers of wiring harnesses, electronic cable assemblies, and cord sets, along with their suppliers and distributors. [1] It publishes the widely used standard IPC/WHMA-A-620 Acceptability of Electronic Wire Harnesses and Cables jointly with IPC. [2]

  3. IDC (electrical connector) - Wikipedia

    en.wikipedia.org/wiki/IDC_(electrical_connector)

    Pin 1 is typically indicated on the body of the connector by a red or raised "V" mark. The corresponding wire in a ribbon cable is usually indicated by red coloration, a raised molded ridge, or markings printed onto the cable insulation. On the connector pin 2 is opposite pin 1, pin 3 is next to pin 1 along the length of the connector, and so on.

  4. Reference designator - Wikipedia

    en.wikipedia.org/wiki/Reference_designator

    1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:

  5. IPC (electronics) - Wikipedia

    en.wikipedia.org/wiki/IPC_(electronics)

    IPC is a trade association whose aim is to standardize the assembly and production requirements of electronic equipment and assemblies. IPC is headquartered in Bannockburn, Illinois, United States with additional offices in Washington, D.C. Atlanta, Ga., and Miami, Fla. in the United States, and overseas offices in China, Japan, Thailand, India, Germany, and Belgium.

  6. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  9. TE Connectivity - Wikipedia

    en.wikipedia.org/wiki/TE_Connectivity

    AMP connector. In 1941, Aircraft and Marine Products (AMP) was founded with electrical connections lacking solder for quick and removable wire connection used for aircraft and ships. After the war time boom, the company had to adapt to the post-war economy, and in 1956, the name of the company was changed to AMP Incorporated when it incorporated.