When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  3. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure , temperature , and liquid level.

  4. Flow control valve - Wikipedia

    en.wikipedia.org/wiki/Flow_control_valve

    The most common final control element in the process control industries is the control valve. The control valve manipulates a flowing fluid, such as gas, steam, water, or chemical compounds, to compensate for the load disturbance and keep the regulated process variable as close as possible to the desired set point.

  5. Mass flow controller - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_controller

    All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...

  6. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    Valves are actuated by an electric motor, hydraulic fluid or air. For air-operated control valves, electrical signals from the control system are converted to an air pressure for the valve actuator in a current/pneumatic I/P converter. Upon loss of pneumatic or hydraulic pressure valves may fail to an open (FO) or fail to a closed (FC) position.

  7. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Pressure independent control valves can be used with any control system. The actuator options give a choice of thermal, 3-point control, or modulating control. This will work with building management systems and individual room controls, in the same way as traditional control valves. The actuators can also be used to set the valve by limiting flow.

  8. Industrial process control - Wikipedia

    en.wikipedia.org/wiki/Industrial_process_control

    The flow control into the tank would be cascaded off the level control. A further example is shown. If a control valve were used to hold level in a tank, the level controller would compare the equivalent reading of a level sensor to the level setpoint and determine whether more or less valve opening was necessary to keep the level constant.

  9. Pressure regulator - Wikipedia

    en.wikipedia.org/wiki/Pressure_regulator

    A back-pressure regulator, back-pressure valve, pressure sustaining valve or pressure sustaining regulator is a control valve that maintains the set pressure at its inlet side by opening to allow flow when the inlet pressure exceeds the set value.