When.com Web Search

  1. Ads

    related to: how to duct an erv 2 box with water connection 1 3

Search results

  1. Results From The WOW.Com Content Network
  2. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  3. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    An air handling unit used for the heating and cooling air: (1) supply air (2) fan section (3) vibration isolator (4) cooling coil (5) filter (6) mixed air duct. Air supply to a building is generally performed by an air handling unit. The process may include filtering, heating, cooling, humidification, or dehumidification, all of which consume ...

  4. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    The duct flange normally has 3/4" bolts at 6" nominal; spacing. Duct flange angle thickness needs to be designed for duct plate tensile stresses, as flanges will bend. 5/16" or 3/8" angle thicknesses are common. See above photo of round duct elbows, transitions, and stiffeners. The duct elbow radius is from 1 1/2 to 2 times the duct diameter.

  5. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    An air handler is usually a large metal box containing a blower, furnace or A/C elements, filter racks or chambers, sound attenuators, and dampers. [2] Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU, sometimes exhausting air to the atmosphere and ...

  6. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  7. Room air distribution - Wikipedia

    en.wikipedia.org/wiki/Room_air_distribution

    Displacement ventilation systems supply air directly to the occupied zone.The air is supplied at low velocities to cause minimal induction and mixing. This system is used for ventilation and cooling of large high spaces, such as auditorium and atria, where energy may be saved if only the occupied zone is treated rather than trying to control the conditions in the entire space.