When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Optical beam smoke detector - Wikipedia

    en.wikipedia.org/wiki/Optical_beam_smoke_detector

    An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, [1] typically as an indicator of fire. [2] They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical [ 3 ] or restricted for use by the height of the building.

  3. Optical spectrometer - Wikipedia

    en.wikipedia.org/wiki/Optical_spectrometer

    The first spectrographs used photographic paper as the detector. The plant pigment phytochrome was discovered using a spectrograph that used living plants as the detector. More recent spectrographs use electronic detectors, such as CCDs which can be used for both visible and UV light. The exact choice of detector depends on the wavelengths of ...

  4. Tyndall effect - Wikipedia

    en.wikipedia.org/wiki/Tyndall_effect

    In the 1860s, Tyndall did a number of experiments with light, shining beams through various gases and liquids and recording the results. In doing so, Tyndall discovered that when gradually filling the tube with smoke and then shining a beam of light through it, the beam appeared to be blue from the sides of the tube but red from the far end. [3]

  5. Spectrophotometry - Wikipedia

    en.wikipedia.org/wiki/Spectrophotometry

    A single-beam spectrophotometer measures the relative light intensity of the beam before and after a test sample is inserted. Although comparison measurements from double-beam instruments are easier and more stable, single-beam instruments can have a larger dynamic range and are optically simpler and more compact.

  6. Fourier-transform infrared spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Fourier-transform_infrared...

    Rather than shining a monochromatic beam of light (a beam composed of only a single wavelength) at the sample, this technique shines a beam containing many frequencies of light at once and measures how much of that beam is absorbed by the sample. Next, the beam is modified to contain a different combination of frequencies, giving a second data ...

  7. Evaporative light scattering detector - Wikipedia

    en.wikipedia.org/wiki/Evaporative_light...

    In this region, a beam of light crosses the column of analyte and the scattering of light is measured by a photodiode or photomultiplier tube. The detector's output is non-linear across more than one order of magnitude and proper calibration is required for quantitative analysis.

  8. Coherent anti-Stokes Raman spectroscopy - Wikipedia

    en.wikipedia.org/wiki/Coherent_anti-Stokes_Raman...

    Under certain beam geometries, the anti-Stokes emission may diffract away from the probe beam, and can be detected in a separate direction. While intuitive, this classical picture does not take into account the quantum mechanical energy levels of the molecule. Quantum mechanically, the CARS process can be understood as follows.

  9. X-ray photoelectron spectroscopy - Wikipedia

    en.wikipedia.org/wiki/X-ray_photoelectron...

    In those, a quartz monochromator system diffracts the Bremsstrahlung X-rays out of the X-ray beam, which means the sample is only exposed to one narrow band of X-ray energy. For example, if aluminum K-alpha X-rays are used, the intrinsic energy band has a FWHM of 0.43 eV, centered on 1,486.7 eV (E/ΔE = 3,457).