Description: Separate excitation of an electric generator. DC generator with commutation is shown, but the principle also applies to AC alternators. Page 175, Figure 183 Main Wikipedia article: Gramme machine Description: A one pole, two coil Gramme ring. The second coil is wired in series with the first and the voltage of both is added together.
A generator interlock kit (or a transfer switch), eliminates the need for extension cords to power appliances. [2]Like a transfer switch, an interlock kit lets the generator energize the panel and all of its circuits (up to the load capacity of the generator); not just corded appliances.
The mid-size stationary engine–generator pictured here is a 100 kVA set which produces 415 V at around 110 A. It is powered by a 6.7-liter turbocharged Perkins Phaser 1000 Series engine, and consumes approximately 27 liters of fuel an hour, on a 400-liter tank.
Set sizes range from 8 to 30-kW (also 8 to 30-kVA single phase) for homes, small shops, and offices, with the larger industrial generators from 8-kW (11 kVA) up to 2,000-kW (2,500-kVA three phase) used for office complexes, factories, and other industrial facilities. A 2,000-kW set can be housed in a 40 ft (12 m) ISO container with a fuel tank ...
I think that unit of generator should be in KW not in KVA, b/c when we write KVA then, it gives an idea of having power factor and in generator there is not any concept of power factor. Plz clear it. 202.125.143.68 21:25, 23 October 2006 (UTC) [ reply ]
It is also known as a unipolar generator, acyclic generator, disk dynamo, or Faraday disc. The voltage is typically low, on the order of a few volts in the case of small demonstration models, but large research generators can produce hundreds of volts, and some systems have multiple generators in series to produce an even larger voltage. [ 18 ]
As an example, a 250 kVA motor–generator operating at 300 ampere of full load current will require 1550 ampere of in-rush current during a re-closure after 5 seconds. This example used a fixed mounted flywheel sized to result in a 1 ⁄ 2 Hz per second slew rate. The motor–generator was a vertical type two-bearing machine with oil-bath ...
A resistive load bank, therefore, removes energy from the complete system: load bank from generator—generator from prime mover—prime mover from fuel. Additional energy is removed as a consequence of resistive load bank operation: waste heat from coolant, exhaust and generator losses and energy consumed by accessory devices.