When.com Web Search

  1. Ads

    related to: hot water relief valve replacement requirements

Search results

  1. Results From The WOW.Com Content Network
  2. Relief valve - Wikipedia

    en.wikipedia.org/wiki/Relief_valve

    A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Discharge from the relief device is an indication that either of the two check valves is 'passing' (leaking past their shutoff seats) or the relief valve itself is faulty. Some normal water use conditions may cause short episodes of discharge (this is why check one has a minimum passing value of relief +3.

  4. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    When the pilot valve reaches set pressure it opens and releases the pressure from the dome. The piston is then free to open and the main valve exhausts the system fluid. The control pilot opens either to the main valve exhaust pipe or to atmosphere. Snap acting At set pressure the valve snaps to full lift.

  5. Safety valve - Wikipedia

    en.wikipedia.org/wiki/Safety_valve

    An oxygen safety relief valve DN250-safety valves. A safety valve is a valve that acts as a fail-safe.An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits.

  6. National Board of Boiler and Pressure Vessel Inspectors

    en.wikipedia.org/wiki/National_Board_of_Boiler...

    Accredited repair organizations qualify to stamp the National Board VR symbol on repair nameplates. [ 3 ] The National Board lab supports industry research and development by testing new designs, serving as a comparative standard for other laboratories, validating new concepts, and – upon jurisdiction request – assist in boiler and pressure ...

  7. Water heating - Wikipedia

    en.wikipedia.org/wiki/Water_heating

    The result of automatically mixing hot and cold water via a tempering valve is referred to as "tempered water". [14] A tempering valve mixes enough cold water with the hot water from the heater to keep the outgoing water temperature fixed at a more moderate temperature, often set to 50 °C (122 °F).