When.com Web Search

  1. Ads

    related to: heat load calculation for air conditioning units prices lennox

Search results

  1. Results From The WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  4. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an improvement over: = Where: = rate of heat transfer [W] = heat transfer surface area [m 2]

  5. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [ 1 ] [ 2 ] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

  6. Heating degree day - Wikipedia

    en.wikipedia.org/wiki/Heating_degree_day

    Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature . The estimated average heating energy requirements for a given building at a specific location are considered to be directly proportional to the number of HDD at that location.

  7. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    Heating seasonal performance factor (HSPF) is a term used in the heating and cooling industry. HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU ...

  1. Ads

    related to: heat load calculation for air conditioning units prices lennox