Search results
Results From The WOW.Com Content Network
The open-circuit saturation curve (also open-circuit characteristic, OCC) of a synchronous generator is a plot of the output open circuit voltage as a function of the excitation current or field. The curve is typically plotted alongside the synchronous impedance curve .
Another way to avoid the transformer inrush current is a "transformer switching relay". This does not need time for cool down. It can also deal with power-line half-wave voltage dips and is short-circuit-proof. This technique is important for IEC 61000-4-11 tests. Another option, particularly for high-voltage circuits, is to use a pre-charge ...
Capability curves for generators with full converters: D-shape (red), rectangular (green), triangular (blue) The inverter-based resources (like solar photovoltaic (PV) generators, doubly-fed induction generators and full-converter wind generators, also known as "Type 3" and "Type 4" turbines [5]) need to have reactive capabilities in order to contribute to the grid stability, yet their ...
Paschen's law is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. [2] [3] It is named after Friedrich Paschen who discovered it empirically in 1889. [4]
In a synchronous generator, [1] the short circuit ratio is the ratio of field current required to produce rated armature voltage at the open circuit to the field current required to produce the rated armature current at short circuit. [1] [2] This ratio can also be expressed as an inverse of the saturated [3] direct-axis synchronous reactance ...
The points where the characteristic curve and the load line intersect are the possible operating point(s) of the circuit; at these points the current and voltage parameters of both parts of the circuit match. [1] The example at right shows how a load line is used to determine the current and voltage in a simple diode circuit.
Synchronous impedance curve (short-circuit characteristic curve), showing armature current as function of field current. The curve is obtained by rotating the generator at the rated RPM with the output terminals shorted and the output current going to 100% of the rated for the device (higher values are typically not tested to avoid overheating).
Definition of open-circuit voltage. The box is any two-terminal device, such as a battery or solar cell. The two terminals are not connected to anything (an open circuit), so no current can flow into or out of either terminal. The voltage v oc between the terminals is the open-circuit voltage of the device.