Search results

  1. Results From The WOW.Com Content Network
  2. Sprinkler fitting - Wikipedia

    en.wikipedia.org/wiki/Sprinkler_fitting

    Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.

  3. Booster pump - Wikipedia

    en.wikipedia.org/wiki/Booster_pump

    The engine needs a fuel tank and an automatic controller that will start the booster pump when it is needed. A small auxiliary electrically-powered booster pump (called a "jockey pump") is often included in the system to maintain the sprinkler pipes at sufficient pressure, without requiring startup of the large diesel engine.

  4. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...

  5. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    A jockey pump, also known as a pressure-maintenance pump, is a small pump connected to a fire suppression system near the fire pump and is intended to maintain pressure in a fire protection piping system. These pumps recover pressures lost from gradual, slow pressure declines in a system due to temperature changes, trapped air escapement, or ...

  6. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  7. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.

  8. Fire hydrant - Wikipedia

    en.wikipedia.org/wiki/Fire_hydrant

    This is done by vacuuming the air out of the dry hydrant, hard sleeve, and the fire engine pump with a primer. Because lower pressure now exists at the pump intake, atmospheric pressure on the water and the weight of the water forces water into the above-water portion of the dry hydrant, into the hard sleeve, and finally into the pump.

  9. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.