Search results
Results From The WOW.Com Content Network
In refrigeration and air conditioning systems, the suction pressure' (also called the low-side pressure) is the intake pressure generated by the system compressor while operating. The suction pressure, along with the suction temperature the wet bulb temperature of the discharge air are used to determine the correct refrigerant charge in a system.
Discharge pressure (also called high side pressure or head pressure) is the pressure generated on the output side of a gas compressor in a refrigeration or air conditioning system. The discharge pressure is affected by several factors: size and speed of the condenser fan, condition and cleanliness of the condenser coil, and the size of the ...
R-407C is a mixture of hydrofluorocarbons used as a refrigerant. It is a zeotropic blend of difluoromethane (R-32), pentafluoroethane (R-125), and 1,1,1,2-tetrafluoroethane (R-134a). Difluoromethane serves to provide the heat capacity, pentafluoroethane decreases flammability, tetrafluoroethane reduces pressure. [1] R-407C cylinders are colored ...
R-410A is a refrigerant used in air conditioning and heat pump applications. It is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125). R-410A is sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A.
A condenser unit used in central air conditioning systems typically has a heat exchanger section to cool down and condense incoming refrigerant vapor into liquid, a compressor to raise the pressure of the refrigerant and move it along, and a fan for blowing outside air through the heat exchanger section to cool the refrigerant inside. A typical ...
Refrigeration has many applications, including household refrigerators, industrial freezers, cryogenics, and air conditioning. [5] [6] [7] Heat pumps may use the heat output of the refrigeration process, and also may be designed to be reversible, but are otherwise similar to air conditioning units. [5]
1,2-Dichlorotetrafluoroethane, or R-114, also known as cryofluorane , is a chlorofluorocarbon (CFC) with the molecular formula ClF 2 CCF 2 Cl. Its primary use has been as a refrigerant . It is a non-flammable gas with a sweetish, chloroform -like odor with the critical point occurring at 145.6 °C and 3.26 MPa.
In refrigeration systems, subcooling the refrigerant is necessary to ensure the completion of the remaining stages of the refrigeration cycle. The subcooling stage provides certainty that the refrigerant is fully liquid before it reaches the next step on the cycle, the thermal expansion valve, where the presence of gas can be disruptive. [1]