A grounding transformer. A grounding transformer or earthing transformer is a type of auxiliary transformer used in three-phase electric power systems to provide a ground path to either an ungrounded wye or a delta-connected system. [1] [2] Grounding transformers are part of an earthing system of the network.
Any Δ-Y (delta-wye) connected transformer may be used for the purpose. A nine winding transformer (a "zig zag" transformer) may be used to balance the phase currents of a delta connected source with an unbalanced load. Low-resistance grounding systems use a neutral grounding resistor (NGR) to limit the fault current to 25 A or greater.
An earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground, typically the equipment's conductive surface, for safety and functional purposes. [1] The choice of earthing system can affect the safety and electromagnetic compatibility of the installation.
High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.
A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.
The ground shield of S, along with the ground wire ("third wire") P in the components' power cord and the building's utility ground wiring G form a ground loop. One of the best ways to prevent such a ground loop is to insert an isolation transformer in the signal cable S, as shown. The transformer breaks the conductive path between the ground ...
Parallel operations: All the transformers should have same phase rotation, vector group, tap setting & polarity of the winding. Ground fault Relay: A Dd transformer does not have neutral. To restrict the ground faults in such systems, we may use a zigzag wound transformer to create a neutral along with the ground fault relay.
Separate grounds for power and safety are also used. Duplication of the ground points assures that the system is still safe if either of the grounds is damaged. A good earth connection is normally a 6 m stake of copper-clad steel driven vertically into the ground, and bonded to the transformer earth and tank.