  1. Results From The WOW.Com Content Network
  2. Aseptic processing - Wikipedia

    en.wikipedia.org/wiki/Aseptic_processing

    Equipment used in aseptic processing of food and beverages must be sterilized before processing and remain sterile during processing. [1] When designing aseptic processing equipment there are six basic requirements to consider: the equipment must have the capability of being cleaned thoroughly, it must be able to be sterilized with steam, chemicals, or high-temperature water, sterilization ...

  3. Z-value (temperature) - Wikipedia

    en.wikipedia.org/wiki/Z-value_(temperature)

    "F 0" is defined as the number of equivalent minutes of steam sterilization at temperature 121.1 °C (250 °F) delivered to a container or unit of product calculated using a z-value of 10 °C. The term F-value or "F Tref/z " is defined as the equivalent number of minutes to a certain reference temperature (T ref ) for a certain control ...

  4. Moist heat sterilization - Wikipedia

    en.wikipedia.org/wiki/Moist_heat_sterilization

    Pressure sterilization is the prevailing method used for medical sterilization of heat-resistant tools, and for sterilization of materials for microbiology and other fields calling for aseptic technique. [citation needed] In cases when items need to be sterilized for immediate use, flash sterilization may be employed. [3]

  5. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    This method is a faster process than dry heat sterilization. Steam sterilization is performed using an autoclave, sometimes called a converter or steam sterilizer. The object or liquid is placed in the autoclave chamber, which is then sealed and heated using pressurized steam to a temperature set point for a defined period of time.

  6. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    Some computer-controlled autoclaves use an F 0 (F-nought) value to control the sterilization cycle. F 0 values are set for the number of minutes of sterilization equivalent to 121 °C (250 °F) at 103 kPa (14.9 psi) above atmospheric pressure for 15 minutes. Since exact temperature control is difficult, the temperature is monitored, and the ...

  7. Biological indicator evaluation resistometer - Wikipedia

    en.wikipedia.org/wiki/Biological_indicator...

    A BIER vessel evaluates the resistance of biological indicators to moist heat sterilization. [1] For example, if a 90% reduction is determined to be 5 minutes for the microorganism being evaluated, then a D-value of 5 is assigned. D values are specific to starting bioload, substrate (the material the spores are on), and microbe species.

  8. Ultra-high-temperature processing - Wikipedia

    en.wikipedia.org/wiki/Ultra-high-temperature...

    Infusion-based, where the liquid is pumped through a nozzle into a chamber with high-pressure steam at a relatively low concentration, providing a large surface contact area. This method achieves near-instantaneous heating and cooling and even distribution of temperature, avoiding local overheating.

  9. Steam - Wikipedia

    en.wikipedia.org/wiki/Steam

    An autoclave, which uses steam under pressure, is used in microbiology laboratories and similar environments for sterilization. Steam, especially dry (highly superheated) steam, may be used for antimicrobial cleaning even to the levels of sterilization. Steam is a non-toxic antimicrobial agent. [11] [12]