When.com Web Search

  1. Ads

    related to: immediate use steam sterilization parameters for water

Search results

  1. Results From The WOW.Com Content Network
  2. Moist heat sterilization - Wikipedia

    en.wikipedia.org/wiki/Moist_heat_sterilization

    Pressure sterilization is the prevailing method used for medical sterilization of heat-resistant tools, and for sterilization of materials for microbiology and other fields calling for aseptic technique. [citation needed] In cases when items need to be sterilized for immediate use, flash sterilization may be employed. [3]

  3. Z-value (temperature) - Wikipedia

    en.wikipedia.org/wiki/Z-value_(temperature)

    "F 0" is defined as the number of equivalent minutes of steam sterilization at temperature 121.1 °C (250 °F) delivered to a container or unit of product calculated using a z-value of 10 °C. The term F-value or "F Tref/z " is defined as the equivalent number of minutes to a certain reference temperature (T ref ) for a certain control ...

  4. Aseptic processing - Wikipedia

    en.wikipedia.org/wiki/Aseptic_processing

    Equipment used in aseptic processing of food and beverages must be sterilized before processing and remain sterile during processing. [1] When designing aseptic processing equipment there are six basic requirements to consider: the equipment must have the capability of being cleaned thoroughly, it must be able to be sterilized with steam, chemicals, or high-temperature water, sterilization ...

  5. Sterilization (microbiology) - Wikipedia

    en.wikipedia.org/wiki/Sterilization_(microbiology)

    Typical steam sterilization cycles are between 3 and 30 minutes at 121–134 °C (250–273 °F) at 100 kPa (15 psi), but adjustments may be made depending on the bioburden of the article being sterilized, its resistance to steam sterilization, the article's heat tolerance, and the required sterility assurance level. Following the completion of ...

  6. Ultra-high-purity steam for oxidation and annealing - Wikipedia

    en.wikipedia.org/wiki/Ultra-high-purity_steam...

    A new approach is the use of High Temperature Steam Annealing (HSA), which uses water vapor at 250–400 °C. In HSA, water vapor applied in a furnace can improve the density of oxides without the use of hydrogen. The steam readily inserts H and O atoms into the Si/SiO 2 interface, and is much faster than FGA and comparable to the HRA process ...

  7. Steam - Wikipedia

    en.wikipedia.org/wiki/Steam

    Steam is also useful in melting hardened grease and oil residues, so it is useful in cleaning kitchen floors and equipment and internal combustion engines and parts. Among the advantages of using steam versus a hot water spray are the facts that steam can operate at higher temperatures and it uses substantially less water per minute. [13]

  8. Autoclave - Wikipedia

    en.wikipedia.org/wiki/Autoclave

    The higher water use by jacketed autoclaves resulted in an estimated water cost of $764 per jacketed autoclave per year, compared to $23 for non-jacketed autoclaves. With over 100 steam-jacketed autoclaves on campus, the author calculated that using jacketed autoclaves for research tasks translated into an additional $74,000 in annual excess ...

  9. Ultra-high-temperature processing - Wikipedia

    en.wikipedia.org/wiki/Ultra-high-temperature...

    There are three types of exchangers in use: [15] Plate exchangers, Tubular exchangers; Scraped-surface exchangers. For higher efficiency, pressurized water or steam is used as the medium for heating the exchangers themselves, accompanied with a regeneration unit which allows reuse of the medium and energy saving. [14]