Search results

  1. Results From The WOW.Com Content Network
  2. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    In that case, the wire is not tri-rated. According to UL 758, the maximum operating temperature of tri-rated cable is 105 °C. British Standard BS 6231 requires only a maximum operating temperature of 90 °C for continuous use. UL and CSA give tri-rated cable a voltage rating of 600 V, while it is rated at 1000 V in the BS 6231 standard.

  3. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  4. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    If heat is produced at a sufficient rate, the conductor temperature rises and the insulation can be damaged or ultimately the conductor itself can sag or melt. The ampacity rating for a conductor is based on the conductor diameter, material used (copper or aluminum), the rated maximum application temperature, and the installation conditions.

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission.

  6. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    In electrical engineering, Neher–McGrath is a method of estimating the steady-state temperature of electrical power cables for some commonly encountered configurations. By estimating the temperature of the cables, the safe long-term current-carrying capacity of the cables can be calculated.

  7. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    One important property of the insulation which affects the current-carrying capacity of the wire is the maximum conductor temperature. This, in combination with the ambient temperature and ability of the environment to absorb heat, determines the amount of tolerable copper loss in the wire, and therefore its size in relation to the load current ...

  8. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    Power cables use stranded copper or aluminum conductors, although small power cables may use solid conductors in sizes of up to 1/0. (For a detailed discussion on copper cables, see: Copper wire and cable.). The cable may include uninsulated conductors used for the circuit neutral or for ground (earth) connection.

  9. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    An electrical cable is an assembly of one or more wires running side by side or bundled, which is used as an electrical conductor to carry electric current. Electrical cables are used to connect two or more devices, enabling the transfer of electrical signals, power, or both from one device to the other. Physically, an electrical cable is an ...