When.com Web Search

  1. Ads

    related to: chemical ionization in mass spectrometry

Search results

  1. Results From The WOW.Com Content Network
  2. Chemical ionization - Wikipedia

    en.wikipedia.org/wiki/Chemical_ionization

    Chemical ionization (CI) is a soft ionization technique used in mass spectrometry. [ 1 ] [ 2 ] This was first introduced by Burnaby Munson and Frank H. Field in 1966. [ 3 ] This technique is a branch of gaseous ion-molecule chemistry. [ 2 ]

  3. Mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Mass_spectrometry

    Techniques for ionization have been key to determining what types of samples can be analyzed by mass spectrometry. Electron ionization and chemical ionization are used for gases and vapors. In chemical ionization sources, the analyte is ionized by chemical ion-molecule reactions during collisions in the source.

  4. Sample preparation in mass spectrometry - Wikipedia

    en.wikipedia.org/wiki/Sample_preparation_in_mass...

    [4] [5] Mass spectrometry ionization techniques requiring the sample to be in the gas phase have similar concerns. Electron ionization (EI) in mass spectrometry requires samples that are small molecules, volatile, and thermally stable, similar to that of gas chromatography. This ensures that as long as GC is performed on the sample before ...

  5. Atmospheric-pressure chemical ionization - Wikipedia

    en.wikipedia.org/wiki/Atmospheric-pressure...

    Atmospheric pressure chemical ionization chamber cross section. Atmospheric pressure chemical ionization (APCI) is an ionization method used in mass spectrometry which utilizes gas-phase ion-molecule reactions at atmospheric pressure (10 5 Pa), [1] [2] commonly coupled with high-performance liquid chromatography (HPLC). [3]

  6. Soft Ionization by Chemical Reaction in Transfer - Wikipedia

    en.wikipedia.org/wiki/Soft_Ionization_by...

    The SICRIT ion source allows for coupling with various types of chromatography (GC, HPLC, SFC, etc.) as interface technology to any atmospheric pressure mass spectrometer (LC-MS). The ionization with its characteristics (see above) is not influenced by the coupling, allowing the same ionization method to be used for different chromatography ...

  7. Gas-phase ion chemistry - Wikipedia

    en.wikipedia.org/wiki/Gas-phase_ion_chemistry

    It is the science that studies ions and molecules in the gas phase, most often enabled by some form of mass spectrometry. ... In chemical ionization, ...

  8. Mass spectral interpretation - Wikipedia

    en.wikipedia.org/wiki/Mass_spectral_interpretation

    [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass spectrometry. [3] [4] Organic chemists obtain mass spectra of chemical compounds as part of structure elucidation and the analysis is part of many organic chemistry ...

  9. Atmospheric-pressure photoionization - Wikipedia

    en.wikipedia.org/wiki/Atmospheric-pressure_photo...

    Atmospheric pressure photoionization (APPI) is a soft ionization method used in mass spectrometry (MS) usually coupled to liquid chromatography (LC). Molecules are ionized using a vacuum ultraviolet (VUV) light source operating at atmospheric pressure (105 Pa), either by direct absorption followed by electron ejection or through ionization of a ...