  1. Results From The WOW.Com Content Network
  2. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    A delta-wye transformer is a type of three-phase electric power transformer design that employs delta-connected windings on its primary and wye/star connected windings on its secondary. A neutral wire can be provided on wye output side. It can be a single three-phase transformer, or built from three independent single-phase units. An equivalent ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    As a delta configuration connects a load across phases of a transformer, it delivers the line-to-line voltage difference, which is √ 3 times greater than the line-to-neutral voltage delivered to a load in the wye configuration. As the power transferred is V 2 /Z, the impedance in the delta configuration must be 3 times what it would be in a ...

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    A three-phase system may be arranged in delta (∆) or star (Y) (also denoted as wye in some areas, as symbolically it is similar to the letter 'Y'). A wye system allows the use of two different voltages from all three phases , such as a 230/400 V system which provides 230 V between the neutral (centre hub) and any one of the phases, and 400 V ...

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    A wye distribution system is preferred because the transformers present unbalanced loads on the line that cause currents in the neutral wire and are then grounded. However, with a delta distribution system, the unbalanced loads can cause variations in the voltages on the 3-phase wires.

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Rural electrification systems tend to use higher distribution voltages because of the longer distances covered by distribution lines (see Rural Electrification Administration). 7.2, 12.47, 25, and 34.5 kV distribution is common in the United States; 11 kV and 33 kV are common in the UK, Australia and New Zealand; 11 kV and 22 kV are common in ...

  7. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta (also known as wild-leg, stinger leg, bastard leg, high-leg, orange-leg, red-leg, dog-leg delta) is a type of electrical service connection for three-phase electric power installations. It is used when both single and three-phase power is desired to be supplied from a three phase transformer (or transformer bank).

  8. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    Examples of connections are wye-delta, delta-wye, delta-delta, and wye-wye. A vector group indicates the configuration of the windings and the phase angle difference between them. If a winding is connected to earth , the earth connection point is usually the center point of a wye winding.

  9. Vector group - Wikipedia

    en.wikipedia.org/wiki/Vector_group

    For example, a transformer with a vector group of Dy1 has a delta-connected HV winding and a wye-connected LV winding. The phase angle of the LV winding lags the HV by 30 degrees. Note that the high-voltage (HV) side always comes before the low-voltage (LV) side, regardless of which is the primary winding.