Unlock and open, then close and relock the vent and drain valves. Unlock and open door, load pig into launcher, close and lock door. Unlock and open valves V1 and V3, to create a flow path through the launcher. Partly close ‘kicker’ valve V2 to launch the pig. The launch alarm XA will indicate when the pig has been launched. Open valve V2 ...
A blowdown valve (BDV) is a type of shutdown valve designed to depressurize a pressure vessel by directing vapour to a flare, vent or blowdown stack in an emergency. BDVs fail-safe to the open position upon failure of the control system. [1] The type of valve, type of actuation and performance measurement are similar to an ESD valve.
A clean-in-place unit on display at the World of Coca-Cola in Atlanta. Clean-in-place (CIP) is an automated method of cleaning the interior surfaces of pipes, vessels, equipment, filters and associated fittings, without major disassembly. CIP is commonly used for equipment such as piping, tanks, and fillers.
Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.
Partial stroke testing (or PST) is a technique used in a control system to allow the user to test a percentage of the possible failure modes of a shut down valve without the need to physically close the valve. PST is used to assist in determining that the safety function will operate on demand.
The blue valve body is visible in-line with the pipe. The valve actuator opens or closes the butterfly disc of the valve based on electrical signals sent to the actuator. Another valve actuator is visible in the background, with windows to indicate the valve position. A valve actuator is the mechanism for opening and closing a valve. Manually ...
If and when a "fail-safe" system fails, it remains at least as safe as it was before the failure. [1] [2] Since many types of failure are possible, failure mode and effects analysis is used to examine failure situations and recommend safety design and procedures. [3] Some systems can never be made fail-safe, as continuous availability is needed.
An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes. [1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system. [2]