When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Condenser (optics) - Wikipedia

    en.wikipedia.org/wiki/Condenser_(optics)

    A condenser (right) and its respective diaphragm (left) A condenser is an optical lens that renders a divergent light beam from a point light source into a parallel or converging beam to illuminate an object to be imaged. Condensers are an essential part of any imaging device, such as microscopes, enlargers, slide

  3. Köhler illumination - Wikipedia

    en.wikipedia.org/wiki/Köhler_illumination

    Köhler illumination is a method of specimen illumination used for transmitted and reflected light (trans- and epi-illuminated) optical microscopy.Köhler illumination acts to generate an even illumination of the sample and ensures that an image of the illumination source (for example a halogen lamp filament) is not visible in the resulting image.

  4. Phase telescope - Wikipedia

    en.wikipedia.org/wiki/Phase_telescope

    A phase telescope or Bertrand lens is an optical device used in aligning the various optical components of a light microscope.In particular it allows observation of the back focal plane of the objective lens and its conjugated focal planes.

  5. Traveling microscope - Wikipedia

    en.wikipedia.org/wiki/Traveling_microscope

    A traveling microscope. E—eyepiece, O—objective, K—knob for focusing, V—vernier, R—rails, S—screw for fine position adjustment. A travelling microscope is an instrument for measuring length with a resolution typically in the order of 0.01mm.

  6. Inverted microscope - Wikipedia

    en.wikipedia.org/wiki/Inverted_microscope

    An inverted microscope is a microscope with its light source and condenser on the top, above the stage pointing down, while the objectives and turret are below the stage pointing up. It was invented in 1850 by J. Lawrence Smith , a faculty member of Tulane University (then named the Medical College of Louisiana).

  7. Phase-contrast microscopy - Wikipedia

    en.wikipedia.org/wiki/Phase-contrast_microscopy

    In a phase-contrast microscope, image contrast is increased in two ways: by generating constructive interference between scattered and background light rays in regions of the field of view that contain the specimen, and by reducing the amount of background light that reaches the image plane. [4]

  8. Transillumination - Wikipedia

    en.wikipedia.org/wiki/Transillumination

    Hydranencephaly is a condition in which the brain's cerebral hemispheres are absent to a great degree and the remaining cranial cavity is filled with cerebrospinal fluid. Transillumination can be used to diagnose hydranencephaly. The device used in this operation is a Chun gun that uses a 150 watt projection bulb as a light source.

  9. Polarized light microscopy - Wikipedia

    en.wikipedia.org/wiki/Polarized_light_microscopy

    Polarizing microscope operating principle Depiction of internal organs of a midge larva via birefringence and polarized light microscopy. Polarized light microscopy can mean any of a number of optical microscopy techniques involving polarized light. Simple techniques include illumination of the sample with polarized light.