When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth.

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped). The circuit breaker contacts must carry the load ...

  5. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [ 5 ] Reclosers are often used as a key component in a smart grid , as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory ...

  6. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    (This does not mean they always do, as practical performance depends on installation details and the discrimination enhancing filtering in the devices.) Therefore, by electrically separating cable armour from the cable circuit protective conductor, a devices can be arranged to protect against cable damage only, and not trip on faults in ...

  7. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...

  8. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  9. Thermal cutoff - Wikipedia

    en.wikipedia.org/wiki/Thermal_cutoff

    An assortment of thermal fuses. A thermal cutoff is an electrical safety device (either a thermal fuse or thermal switch) that interrupts electric current when heated to a specific temperature. These devices may be for one-time use (a thermal fuse), or may be reset manually or automatically (a thermal switch).