Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire
Wire Gauge to Diameter—Diameter to Wire Gauge Converter - Online calculator converts gauge to diameter or diameter to gauge for any wire size. Calculation: round electric cable diameter to circle cross-sectional area and vice versa; Wire gauge conversion chart
A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
In Canada and the United States, the Canadian Electrical Code (CEC) and the National Electrical Code (NEC), respectively, use the circular mil to define wire sizes larger than 0000 AWG. In many NEC publications and uses, large wires may be expressed in thousands of circular mils, which is abbreviated in two different ways: kcmil [ 1 ] or MCM ...
Electric motors; 32 return 31 33 main terminal (swap of 32 and 33 is possible) 30 33a limit 33b field 54e 33f 2. slow rpm: 33g 3. slow rpm 33h 4. slow rpm 33L rotation left 30L 33R rotation right 30R Indicators 49 flasher unit in 15, 15+, 15/54, +, +15, X 49a flasher unit out, indicator switch in 54L, S, S4, L 49b out 2. flasher circuit 49c
Cross-sectional area of electrical wire is measured in circular mils in the U.S. and Canada, one circular mil (cmil) being equal to 5.067 × 10 −4 mm 2 (or 7.854 × 10 −7 in 2). Since this is so small, actual wire is commonly measured in thousands of a cmil, called either kcmil or MCM. The mil or thou is also sometimes used to mean ...
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...