A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Figure 1 provides a schematic diagram of the components of a typical vapor-compression refrigeration system. The thermodynamics of the cycle can be analyzed on a diagram [74] as shown in Figure 2. In this cycle, a circulating refrigerant such as a low boiling hydrocarbon or hydrofluorocarbons enters the compressor as a vapour.
A two-cycle cascade refrigeration process schematic diagram. A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1] In a cascade refrigeration system, two or more vapor-compression cycles with ...
You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.
Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]
Schematic diagram of a cryogen-free, or dry, dilution refrigerator precooled by a two-stage pulse tube refrigerator, indicated by the dotted rectangle. A 3 He/ 4 He dilution refrigerator is a cryogenic device that provides continuous cooling to temperatures as low as 2 mK , with no moving parts in the low-temperature region.
Common absorption refrigerators use a refrigerant with a very low boiling point (less than −18 °C (0 °F)) just like compressor refrigerators.Compression refrigerators typically use an HCFC or HFC, while absorption refrigerators typically use ammonia or water and need at least a second fluid able to absorb the coolant, the absorbent, respectively water (for ammonia) or brine (for water).
A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...