When.com Web Search

  1. Ads

    related to: nfpa 13 sprinkler standards manual instructions

Search results

  1. Results From The WOW.Com Content Network
  2. National Fire Protection Association - Wikipedia

    en.wikipedia.org/wiki/National_Fire_Protection...

    The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [6] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond promulgating ...

  3. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Water flow from sprinklers, needed to control the fire, is delayed until the air is vented from the sprinklers. In regions using NFPA 13 regulations, the time it takes water to reach the hydraulically remote sprinkler from the time that sprinkler is activated is limited to a maximum of 60 seconds.

  4. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The 2002 edition of the NFPA #13 standard, section 3.6.1 defines quick response sprinklers as having a response time index (RTI) of 50 (meter-seconds) 1/2 or less. RTI is a measure of how thermally responsive the heat-responsive element of the sprinkler is, measured as the time needed to raise the temperature of the sprinkler bulb to 63% of the ...

  5. Essentials of Fire Fighting - Wikipedia

    en.wikipedia.org/wiki/Essentials_of_Fire_Fighting

    These standards are widely accepted as the standards of knowledge and skills measurement for all firefighters in North America and beyond. Essentials of Fire Fighting includes an appendix that lists the job performance requirements from the NFPA standards and cross-references those requirements to the chapters within the manual. These chapters ...

  6. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]

  7. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Also known as a closet ladder, folding ladder or "pencil ladder." Required to be carried on pumpers by NFPA 1901. Automatic sprinkler System of pipes serving fire sprinklers, for automatically directing water to a fire when the sprinkler is heated to its actuation temperature (usually 155 deg F).

  8. Sprinkler fitting - Wikipedia

    en.wikipedia.org/wiki/Sprinkler_fitting

    Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.

  9. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...