  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    A small box is 1 mm × 1 mm and represents 0.1 mV × 0.04 seconds. A large box is 5 mm × 5 mm and represents 0.5 mV × 0.20 seconds. The "large" box is represented by a heavier line weight than the small boxes. Measuring time and voltage with ECG graph paper

  3. Automated ECG interpretation - Wikipedia

    en.wikipedia.org/wiki/Automated_ECG_interpretation

    The manufacturing industries of ECG machines is now entirely digital, and many models incorporate embedded software for analysis and interpretation of ECG recordings with 3 or more leads. Consumer products, such as home ECG recorders for simple, 1-channel heart arrhythmia detection, also use basic ECG analysis, essentially to detect abnormalities.

  4. QT interval - Wikipedia

    en.wikipedia.org/wiki/QT_interval

    The QT interval is a measurement made on an electrocardiogram used to assess some of the electrical properties of the heart.It is calculated as the time from the start of the Q wave to the end of the T wave, and approximates to the time taken from when the cardiac ventricles start to contract to when they finish relaxing.

  5. ST segment - Wikipedia

    en.wikipedia.org/wiki/ST_segment

    Schematic representation of normal ECG. In electrocardiography, the ST segment connects the QRS complex and the T wave and has a duration of 0.005 to 0.150 sec (5 to 150 ms). It starts at the J point (junction between the QRS complex and ST segment) and ends at the beginning of the T wave.

  6. ST elevation - Wikipedia

    en.wikipedia.org/wiki/ST_elevation

    An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...

  7. Bruce protocol - Wikipedia

    en.wikipedia.org/wiki/Bruce_protocol

    The test score is the time taken on the test, in minutes. This can also be converted to an estimated maximal oxygen uptake score using the calculator below and the following formulas, where the value "T" is the total time completed (expressed in minutes and fractions of a minute e.g. 9 minutes 15 seconds = 9.25 minutes). As with many exercise ...

  8. PR interval - Wikipedia

    en.wikipedia.org/wiki/PR_interval

    Schematic representation of a normal sinus rhythm EKG wave. In electrocardiography, the PR interval is the period, measured in milliseconds, that extends from the beginning of the P wave (the onset of atrial depolarization) until the beginning of the QRS complex (the onset of ventricular depolarization); it is normally between 120 and 200 ms in duration.

  9. First-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/First-degree_atrio...

    It is usually an incidental finding on a routine ECG. [4] First-degree heart block does not require any particular investigations except for electrolyte and drug screens, especially if an overdose is suspected. [5] In comparison to second-degree atrioventricular block, in first-degree block there is an absence of non-conduction or "dropped beats."