The "local" Earth/Ground electrode provides "system grounding" [13] at each building where it is installed. The "Grounded" current carrying conductor is the system "neutral". Australian and New Zealand standards use a modified protective multiple earthing (PME [ 14 ] ) system called multiple earthed neutral (MEN).
Other grounding electrodes may include buried solid plates, or a grid of buried wires, where soil conditions do not favor driven ground rods. Buried metallic piping systems, well casings or the reinforcing bars of concrete slabs in contact with the earth have all been used as grounding electrodes.
The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices, such as cell phones and media players, as well as circuits in vehicles, may be spoken of as having a "ground" or chassis ground connection without any actual connection to the Earth, despite "common" being ...
An isolated ground (IG) (or Functional Earth (FE) in European literature) is a ground connection to a local earth electrode from equipment where the main supply uses a different earthing arrangement, one of the common earthing arrangements used with domestic mains supplies.
The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...
A hunk of copper is visible that is designed to be easily connected or disconnected from its place between two screws, rated for 600 A (as stamped on it). We also see the thick wires in standard colors (two yellow/green ground and two blue neutral), as well as markings PEN (protected earth and neutral), PE (protective earth) and N (neutral).
This usually means two distinct metal wires in the circuit, but in the earth-return circuit one of these is replaced by connections to earth (also called ground) to complete the circuit. Connection to earth is made by means of metal plates with a large surface area buried deeply in the ground. These plates could be made of copper or galvanised ...
A multipoint ground system is more complicated to install and maintain over the long term, and can be more expensive to install. Star topology systems can be converted to multipoint systems by installing new conductors between old existing ones. However, this should be done with care as it can inadvertently introduce noise onto signal lines during the conversion process. The noise can be ...