When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Droop speed control - Wikipedia

    en.wikipedia.org/wiki/Droop_speed_control

    Droop speed control is a control mode used for AC electrical power generators, whereby the power output of a generator reduces as the line frequency increases. It is commonly used as the speed control mode of the governor of a prime mover driving a synchronous generator connected to an electrical grid .

  3. Voltage droop - Wikipedia

    en.wikipedia.org/wiki/Voltage_droop

    Voltage droop is the intentional loss in output voltage from a device as it drives a load. Adding droop in a voltage regulation circuit increases the headroom for load transients . All electrical systems have some amount of resistance between the regulator output and the load.

  4. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    The load can be shared among parallel-running generators through load sharing. Load sharing can be achieved by using droop speed control controlled by the frequency at the generator, while it constantly adjusts the engine fuel control to shift load to and from the remaining power sources. A diesel generator will take more load when the fuel ...

  5. Automatic generation control - Wikipedia

    en.wikipedia.org/wiki/Automatic_generation_control

    Steady state frequency-power relation for a turbine governor. The purpose of the turbine-governor control (TGC) is to maintain the desired system frequency by adjusting the mechanical power output of the turbine. [2] These controllers have become automated and at steady state, the frequency-power relation for turbine-governor control is,

  6. Electrical grid - Wikipedia

    en.wikipedia.org/wiki/Electrical_grid

    Conversely, when the grid is heavily loaded, the frequency naturally slows, and governors adjust their generators so that more power is output (droop speed control). When generators have identical droop speed control settings it ensures that multiple parallel generators with the same settings share load in proportion to their rating.

  7. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    The voltage, frequency and phase angle must be controlled each time a generator is to be connected to a grid. [1] Generating units for connection to a power grid have an inherent droop speed control that allows them to share load proportional to their rating. Some generator units, especially in isolated systems, operate with isochronous ...

  8. Wide area synchronous grid - Wikipedia

    en.wikipedia.org/wiki/Wide_area_synchronous_grid

    When the grid is heavily loaded, the frequency slows, and governors adjust their generators so that more power is output (droop speed control). When the grid is lightly loaded the grid frequency runs above the nominal frequency, and this is taken as an indication by Automatic Generation Control systems across the network that generators should ...

  9. Governor (device) - Wikipedia

    en.wikipedia.org/wiki/Governor_(device)

    A governor, or speed limiter or controller, is a device used to measure and regulate the speed of a machine, such as an engine.. A classic example is the centrifugal governor, also known as the Watt or fly-ball governor on a reciprocating steam engine, which uses the effect of inertial force on rotating weights driven by the machine output shaft to regulate its speed by altering the input flow ...