When.com Web Search

  1. Ad

    related to: nec above ground pool bonding diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device. [1]: 287

  3. Electrical bonding - Wikipedia

    en.wikipedia.org/wiki/Electrical_bonding

    Equipotential bonding involves electrically connecting metalwork so that it is at the same voltage everywhere. Exact rules for electrical installations vary by country, locality, or supplying power company. [2] Equipotential bonding is done from where the distribution wiring enters the building to incoming water and gas services.

  4. Counterpoise (ground system) - Wikipedia

    en.wikipedia.org/wiki/Counterpoise_(ground_system)

    It consists of a network of radial copper wires suspended above the ground, connected to the transmitter feedline ground. It is suspended about 8 feet above ground, so technicians can get access to the helix house at the foot of the tower. Antenna used in Lodge-Muirhead wireless system around 1900, the first counterpoise.

  5. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Each phase of the circuit is run in a separate grounded metal enclosure. The only fault possible is a phase-to-ground fault, since the enclosures are separated. This type of bus can be rated up to 50,000 amperes and up to hundreds of kilovolts (during normal service, not just for faults), but is not used for building wiring in the conventional ...

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    There are special provisions in the NEC for so-called technical equipment, mainly professional grade audio and video equipment supplied by so-called "balanced" 120 volt circuits. The center tap of a transformer is connected to ground, and the equipment is supplied by two line wires each 60 volts to ground (and 120 volts between line conductors).

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).

  8. Earthing system - Wikipedia

    en.wikipedia.org/wiki/Earthing_system

    The grounding system must also have a minimum of two or more earth pits (electrodes) to better ensure proper grounding. According to rule 42, an installation with a connected load above 5 kW exceeding 250 V shall have a suitable earth leakage protective device to isolate the load in case of earth fault or leakage. [21]

  9. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    Equipment bonding conductors or equipment ground conductors (EGC) provide a low-impedance path between normally non-current-carrying metallic parts of equipment and one of the conductors of that electrical system's source. If any exposed metal part should become energized (fault), such as by a frayed or damaged insulator, it creates a short ...