  2. Center tap - Wikipedia

    en.wikipedia.org/wiki/Center_tap

    For example, a 24 VCT transformer will measure 24 VAC across the outer two taps (winding as a whole), and 12 VAC from each outer tap to the center-tap (half winding). These two 12 VAC supplies are 180 degrees out of phase with each other, measured with respect to the tap, thus making it easy to derive positive and negative 12 volt DC power ...

  3. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    location and specifications for distributed control devices such as tap-changing transformers, switched shunt compensation, static Var compensators, flexible AC transmission systems, etc., location and specifications for protection devices such as relays and load shedding, and

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    A transformer supplying a three-wire distribution system has a single-phase input (primary) winding. The output (secondary) winding has a center tap connected to a grounded neutral. As shown in Fig. 1, either end to center has half the voltage of end-to-end. Fig. 2 illustrates the phasor diagram

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A "delta" (Δ) connected transformer winding is connected between phases of a three-phase system. A "wye" (Y) transformer connects each winding from a phase wire to a common neutral point. A single three-phase transformer can be used, or three single-phase transformers. In an "open delta" or "V" system, only two transformers are used.

  7. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    The 240 V secondary winding is center-tapped, and the center neutral wire is grounded, making the two end conductors "hot" concerning the center tap. These three wires run down the service drop to the building's electric meter and service panel. Connecting a load between the hot wire and the neutral gives 120 volts, which is used for lighting ...